Show simple item record

dc.contributor.authorHaššo, Marek
dc.contributor.authorKudr, Jiří
dc.contributor.authorZítka, Jan
dc.contributor.authorŠílený, Jan
dc.contributor.authorŠvec, Pavel
dc.contributor.authorŠvorc, Ľubomír
dc.contributor.authorZítka, Ondřej
dc.date.accessioned2024-12-06T01:03:22Z
dc.date.available2024-12-06T01:03:22Z
dc.date.issued2024
dc.identifier.issn0026-3672 Sherpa/RoMEO, JCR
dc.identifier.urihttps://repozitar.mendelu.cz/xmlui/handle/20.500.12698/1979
dc.description.abstractThe introduced work represents an implementation of the automatic benchtop electrochemical station (BES) as an effective tool for the possibilities of high-throughput preparation of modified sensor/biosensors, speeding up the development of the analytical method, and automation of the analytical procedure for the determination of paracetamol (PAR) and dopamine (DOP) as target analytes. Within the preparation of gold nanoparticles modified screen-printed carbon electrode (AuNPs-SPCE) by electrodeposition, the deposition potential EDEP, the deposition time tDEP, and the concentration of HAuCl4 were optimized and their influence was monitored on 1 mM [Ru(NH3)6]3+/2+ redox probe and 50 μM DOP. The morphology of the AuNPs-SPCE prepared at various modification conditions was observed by SEM. The analytical performance of the AuNPs-SPCE prepared at different modification conditions was evaluated by a construction of the calibration curves of DOP and PAR. SPCE and AuNPs-SPCE at modification condition providing the best sensitivity to PAR and DOP, were successfully used to determine PAR and DOP in tap water by "spike-recovery" approach. The BES yields better reproducibility of the preparation of AuNPs-SPCE (RSD = 3.0%) in comparison with the case when AuNPs-SPCE was prepared manually by highly skilled laboratory operator (RSD = 7.0%).en
dc.format408
dc.publisherSpringer Wien
dc.relation.ispartofMicrochimica Acta
dc.relation.urihttps://doi.org/10.1007/s00604-024-06454-6
dc.rightsCC BY 4.0
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectAcetaminophenen
dc.subjectElectrodepositionen
dc.subjectScreen-printed electrodeen
dc.subjectDifferential pulse voltammetryen
dc.subjectElectroplatingen
dc.subject.Sensor arrayen
dc.titleProving the automatic benchtop electrochemical station for the development of dopamine and paracetamol sensorsen
dc.typeJ_ČLÁNEK
dc.date.updated2024-12-06T01:03:22Z
dc.description.versionOA-hybrid
local.identifier.doi10.1007/s00604-024-06454-6
local.identifier.scopus2-s2.0-85196422890
local.identifier.wos001250982700002
local.number7
local.volume191
local.identifier.obd43926750
local.identifier.e-issn1436-5073
dc.project.IDEF16_025/0007314
dc.project.IDMultioborový výzkum pro zvýšení aplikačního potenciálu nanomateriálů v zemědělské praxi
dc.identifier.orcidKudr, Jiří 0000-0002-2058-4563
dc.identifier.orcidŠvec, Pavel 0000-0001-7170-3780
dc.identifier.orcidZítka, Ondřej 0000-0001-7607-5058
local.contributor.affiliationAF


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

CC BY 4.0
Except where otherwise noted, this item's license is described as CC BY 4.0