Show simple item record

dc.contributor.authorJunga, Petr
dc.contributor.authorTrávníček, Petr
dc.contributor.authorVítěz, Tomáš
dc.contributor.authorMachů, Gabrielle
dc.contributor.authorRužbarský, Juraj
dc.date.accessioned2023-08-11T00:03:48Z
dc.date.available2023-08-11T00:03:48Z
dc.date.issued2023
dc.identifier.issn2076-3417 Sherpa/RoMEO, JCR
dc.identifier.urihttps://repozitar.mendelu.cz/xmlui/handle/20.500.12698/1755
dc.description.abstractThis paper presents the results of experimental measurements of the number of aerosol particles in cleanroom air of a biotechnology laboratory for DNA analysis. The aerosol content in the air can harm the accuracy of any analysis performed. The experimental measurements demonstrate compliance with the ISO cleanroom requirements for class 7. The indoor environment of the investigated biotechnology laboratory cleanroom can be classified as ISO cleanroom class 8. The particle count values depend on the month in which the measurement is made. The location of the measurement site, on the other hand, does not have too much influence. Our results showed that the values of particle number in the laboratory ranged from 325,965 to 2,740,877 pc/m3 for particles of 0.5 μm and more. From these measurements, it can be concluded that the biotechnology laboratory premises were not very suitable locations to perform for the intended DNA tests since microbiological contamination had the capacity to distort the results of these tests. As such, the authors propose several strategies to improve the current situation. These strategies are based on changing the laboratory work organization and cleaning methodology. In addition, the monitoring of particles with a size of 5 µm or more is recommended.en
dc.format5915
dc.publisherMDPI AG (Multidisciplinary Digital Publishing Institute-MDPI)
dc.relation.ispartofApplied Sciences
dc.relation.urihttps://doi.org/10.3390/app13105915
dc.rightsCC BY 4.0
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectcleanroomen
dc.subjectparticulate contaminationen
dc.subjectaerosolen
dc.subjectfiltrationen
dc.titleParticle Number of Aerosol in Specific Conditions of Biotechnology Laboratory Cleanroomen
dc.typeJ_ČLÁNEK
dc.date.updated2023-08-11T00:03:48Z
dc.description.versionOA
local.identifier.doi10.3390/app13105915
local.identifier.scopus2-s2.0-85160859514
local.identifier.wos000995601300001
local.number10
local.volume13
local.identifier.obd43924878
local.identifier.e-issn2076-3417
dc.identifier.orcidJunga, Petr 0000-0002-4383-4799
dc.identifier.orcidTrávníček, Petr 0000-0003-3184-7880
dc.identifier.orcidVítěz, Tomáš 0000-0003-4442-4481
dc.identifier.orcidMachů, Gabrielle 0000-0001-6128-0112
local.contributor.affiliationAF


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

CC BY 4.0
Except where otherwise noted, this item's license is described as CC BY 4.0